Quadruplex Service Drop
APPLICATION of tano cable Quadruplex Service Drop cable
Used to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulate conductors.
STANDARD of tano cable Quadruplex Service Drop cable
Tano Cable's quadruplex service drop cable meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Tano Cable's quadruplex service drop cable meets or exceeds all applicable requirements of ICEA S-76-474 .
CONSTRUCTION of tano cable Quadruplex Service Drop cable
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR. Conductors are manufactured with ridges for phase identification (one conductor one ridge, one conductor two ridges, one conductor plain.)
TECHNICAL DATA of tano cable Quadruplex Service Drop cable
Code
Phase Conductor
Bare Neutral Messenger
Weight Per 1000 ft.(lbs.)
Allowable Ampacities
Size
Stranding
Insul. Thick.
Equiv. Dia.
Size
Stranding
Rated Strength
XLP
POLY
XLP
POLY
(AWG or kcmil)
(mils)
(AWG)
(kcmil)
(lbs).
Bay
6
1
45
6
30.58
7
1110
137
137
75
60
French Coach
6
7
45
6
30.58
7
1110
146
146
75
60
German Coach
4
1
45
4
48.69
7
1760
205
205
100
80
Arabian
4
7
45
4
48.69
7
1760
217
217
100
80
Belgian
2
7
45
2
77.47
7
2800
328
328
135
105
Shetland
1/0
9
60
1/0
123.3
7
4460
519
519
180
140
Thoroughbred
2/0
11
60
2/0
155.4
7
5390
639
639
205
160
Trotter
3/0
17
60
3/0
195.7
7
6790
789
789
235
185
Walking
4/0
18
60
4/0
246.9
7
8560
977
977
275
210
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Bay/XLP).
+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.
++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.
Code
Phase Conductor
Bare Neutral Messenger
Weight Per 1000 ft.(lbs.)
Allowable Ampacities
Size
Stranding
Insul. Thick.
Size
Stranding
Rated Strength
XLP
POLY
XLP
POLY
(AWG or kcmil)
(mils)
(AWG or
(lbs).
kcmil)
AAC NEUTRAL-MESSENGER
Clydesdale
4
1
45
4
7
881
198
198
100
80
Pinto
4
7
45
4
7
881
211
211
100
80
Mustang
2
7
45
2
7
1350
318
318
135
105
Criollo
1/0
9
60
1/0
7
1990
503
503
180
140
Percheron
2/0
11
60
2/0
7
2510
619
619
205
160
Hanovarian
3/0
17
60
3/0
19
3310
764
764
235
185
Oldenburg
4/0
18
60
4/0
19
4020
945
945
275
210
Lippizaner
336.4
19
80
336.4
19
6146
1519
1519
370
280
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Bay/XLP).
+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.
Code
Phase Conductor
Bare Neutral Messenger
Weight Per 1000 ft.(lbs.)
Allowable Ampacities
Size
Stranding
Insul. Thick.
Size
Stranding
Rated Strength
XLP
POLY
XLP
POLY
(AWG or kcmil)
(mils)
(AWG or
(lbs).
kcmil)
ACSR NEUTRAL-MESSENGER
Morochuca
6
1
45
6
6/1
1190
145
145
75
60
Chola
6
7
45
6
6/1
1190
153
153
75
60
Morgan
4
1
45
4
6/1
1860
217
217
100
80
Hackney
4
7
45
4
6/1
1860
229
229
100
80
Palomino
2
7
45
2
6/1
2850
347
347
135
105
Costena
1/0
9
60
1/0
6/1
4380
549
549
180
140
Grullo
2/0
11
60
2/0
6/1
5310
677
677
205
160
Suffolk
3/0
17
60
3/0
6/1
6620
837
837
235
185
Appaloosa
4/0
18
60
4/0
6/1
8350
1038
1038
275
210
Gelding
336.4
19
80
4/0
6/1
8350
1494
1494
370
280
Bronco
336.4
19
80
336.4
18/1
8680
1568
1568
370
280
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Bay/XLP).
+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.
get more information: http://www.tanocable.com/
skype:tanocable
Tel.:+86-371-60306197 +86-18937105488
Less ...