DESCRIPTION
MY021-D TTL to IR ANSI Type-2converter /optical probe utilize an infra-red LED technology to provide a galvanically isolated, bi-directional communications link between computers and ANSI C12.18-1996 electric utility meters for obtaining meter data, performing site diagnostics and making programming changes. Connecting to a computer or hand-held terminal they permit galvanically isolated communication with electricity and gas smart meters.
FEATURES
*This probe are intended for both-way serial communication with the meter via infrared.
*Compatible with ANSI Type-2 meters.
*ANSI Type-2 Compliant per ANSI C12.18-1996(U.S.A.) and AS 1284.10.2-1993(Australia)
*TTL interface: VCC ,GND ,RXD ,TXD
*Transparent data transmission, supporting all protocols.
*Magnetic Adhesion to Electric Meter Metal “D” Ring
TECHNICAL DATA
*Magnetic Cohesion forcethe steel plate) : Magnetic Adhesion to Electric Meter Metal “D” Ring
* Interface: TTL interface, VCC GND RXD TXD
*Transmission speed [Bd] : 300, 600, 1200, 2400, 4800, 9600, 19200
*Transmission wave lenght[nm]: 800 to 1000
*Power supply : DC3.3V TO DC12V
*Standard: ANSI C12.18-1996
*Cable length: 1.5m
*Working temperature range: - 25 °C to + 70°C
*Weight [kg] : about 0.15