Mainstream Sidestream Capnography Sensor
Complete model: Compatible with equipment from many well-known ... More ...
Mainstream Sidestream Capnography Sensor
Complete model: Compatible with equipment from many well-known manufacturers around the world, with wide compatibility;
Using medical TPU plastic and low impedance wire: It has the advantages of good texture, bending resistance, corrosion resistance, and stable waveform;
Gold-plated nickel-plated equipment end connection hardware and electrode surface: Excellent electrical conductivity, ensuring full contact and reliable connection;
Using imported electronic components: It has the advantages of accurate value and stable waveform. Specification of Side Stream Capnography
Sensor
Project
Specifications
Principle of Operation
Non-dispersive infrared(NDIR) single beam optics, dual wavelength, no moving parts.
Initialization Time
Capnogram displayed in less than 3 seconds, full specifications within 3 minutes(At 25°C)
CO2 Measurement Range
0 - 114 mmHg; 0 - 15 %; 0 - 15.2 kPa
CO2 Rise Time
Rise Time Less than 80 ms
CO2 Resolution
0.1mmHg 0 to 38 mmHg.
0.25 mmHg 39 to 114mmHg.
CO2 Accuracy
0 - 40mmHg ±2 mmHg.
41 - 76mmHg ±5% of reading.
77 - 114 mmHg ±8% of reading.
Above 80 breaths per minute ±12% of reading.
* Note: Gas temperature at 25°C.
CO2 Stability
Short term drift: Drift over four hours shall not exceed 1 mmHg maximum.
Long term drift: Accuracy specification will be maintained over a 120-hour period.
Sampling Frequency
100Hz。
Respiration Rate Range
3 to 150 breaths per minute.
Respiration Rate Accuracy
±1 breath.
Temperature
Operating: 0 to 40°C; Storage: -40 to 70°C; Transport: -40 to 70°C.
Humidity
Operating: 10 to 90% RH, non-condensing; Storage: 10 to 90% RH, non-condensing. Transport: 10 to 90% RH, non-condensing.
Atmospheric Pressure
Operating: 400-800 mmHg; Storage: 400-800 mmHg; Transport: 400-800 mmHg.
Water Resistance
IPX4 - Splash-proof - Sensor only.
Sensor Weight
<250g
Sensor Size
Deep*Wide*High: 102mm*62mm*38mm
Cable Length
0.75m
Details of Sidestream Capnography Sensor
Quick Details of Sidestream Capnography Sensor
Designed for use with monitors and ventilators equipped with a carbon dioxide function, it accurately and swiftly collects end-tidal carbon dioxide values and generates visual curves. Both reusable and disposable consumables are available.
If you want to know more kinds of sidestream capnometer
, please visit our website.
Now the price of capnography monitor for sale
is reasonable, anything you need, please contact us Less ...
|