|
Description
|
OXIMETER WITH BLUETOOTH AND FOR ALL AGE GROUPS :
The newly launched Oxygize
FINGER Pulse ... More ...
OXIMETER WITH BLUETOOTH AND FOR ALL AGE GROUPS :
The newly launched Oxygize
FINGER Pulse Oximeter is an affordable and accurate way to check pulse rates
and blood oxygen saturation levels. Simple one- click design allows for easy
operation. Small portable size makes it easy to handle and carry. It’s the only
oximeter with Bluetooth, so you can keep a track of your oxygen level through
app "OXYCARE" and share graphs and detailed report with your doctors
directly. Helpful for athletes and pilots to obtain quick and accurate oxygen
saturation readings. This is the best pulse oximeter available for medical
professionals as well as home use. The product is water resistant and contains
audio visual alarm. All product designs, packaging designs, product images and
text on this page are protected by various Indian and international patents and
copyrights.
Warranty - 1year extended Warranty (6 months standard warranty) subject to terms
and condition as on our instruction manual and available in select modes of
Oxygize products only. Breakage of pulse oximeter, drops to the floor, water
damage, wear and tear, batteries excluded from warranty. Warranty covers
manufacturing defect inside pulse oximeter sensor only. Customer to send pulse
oximeter to our service centre for instant replacement. Please do not attempt
to repair pulse oximeter yourself /unauthorized repair as this may cause
electric shock and will also void warranty. Caution: This device is not
intended to diagnose or treat any medical condition or disease.
You should not use this
information as self-diagnosis or for treating a health problem or disease. Contact
your health-care provider immediately if you suspect that you have a medical
problem. This device is for sports and aviation only. Statements regarding
dietary supplements have not been evaluated by the FDA and are not intended to
diagnose, treat, cure, or prevent any disease or health condition.
Key Features:
REAL TIME SYNCHRONIZATION:
With free APP “Oxicare” through Bluetooth to record and store the data of blood
oxygen level (SpO2), pulse rate (PR) and perfusion index (PI) on cloud and
share with your doctor directly.
PERFECT PULSE RATE DETECTOR: This awesome device
might be small but it is also very powerful. When it comes to monitoring your
oxygen saturation level and your pulse rate, this devices is very accurate with
a measurement range of 25 ~ 250bpm and an accuracy of ±2bpm. Despite its small
and simple looks, it is very effective and will never let you down.
LOADED WITH ACCESSORIES - Include 2X AAA
BATTERIES that will allow you to use the pulse oximeter right out of the box, a
LANYARD for convenience. Comes with 12 months WARRANTY and Indian based
technical phone support. Accurate and sensitive get readings even if blood
perfusion index is as low as 0.2%
SPORT/HEALTH - For sports people like mountain
climbers, skiers, bikers or anyone interested in measuring their SpO2 and pulse
rate. SpO2 and Pulse Rate now instead of away from the user for easy
read.
PRO SERIES -Manufactured according to CE and FDA
standards for pulse oximeters used by doctors and other health professionals.
The ONLY LED pulse oximeter that can read and display up to 100% for SpO2
value.
Measuring Steps –
1. Hold the product in one hand with
the front panel facing the palm. Put the other hand's big Finger on the battery
cabinet lid's press sign, press downwards and push the lid open at the same
time.
2. Install batteries into the slots per
the "+" and "-" symbols. Cover the lid onto the cabinet and
push it upwards to make it close well.
3. Press clip's press sign. Place the
tester's finger into the rubber cushions of the clip. Make sure the finger is
in the right position. Use the first finger, middle finger or ring finger.
4. Press the power and function switch
button on the front panel to turn on the product. Don't shake the finger and
keep the tester at ease during the process. The readings will be displayed on
the LCD screen a moment later.
Other information
1. Before measuring, ensure that the
pulse oximeter is in a normal state. If it is damaged, please don't use.
2. Don't put the pulse oximeter on
extremities with an arterial catheter or venous syringe.
3. Don't perform SpO₂ monitoring and
NIBP measurements on the same arm simultaneously. Obstruction of blood flow
during NIBP measurements may adversely affect the reading of the SpO₂ value.
4. Don't use the pulse oximeter for
patients whose pulse rate is lower than 30bpm, as this may cause incorrect
results.
5. The measurement part(finger) should
be well perfused and able to cover the test window of the sensor adequately.
Please clean the measurement part and ensure that it's dry before placing the
pulse oximeter.
6. Cover the sensor with the opaque
material under the condition of intense light. Failure to do so will result in
inaccurate measurement.
7. Make sure that there is no
contamination and scar on the tested part. Otherwise, the measured result may
be incorrect because the signal received by the sensor is affected.
8. When used on different patients, the
product is prone to cross- contamination, which should be prevented and
controlled by the user. Disinfection is recommended before using the product on
other patients.
9. Incorrect placement of the sensor
may affect the accuracy of the measurement, and if it is at the same horizontal
position with heart, measurement effect is the best.
10. The highest temperature of sensor
contact with the patient's skin should not exceed 41°C.
11. Prolonged use or the
patient's condition may require changing the sensor site periodically. Change
sensor site and check skin integrity, circulatory status, and correct alignment
at least even 2 hours. Less ...
|
Packaging
Packing |
Packaging Size |
Package Weight |
10piecesperbox |
58 x 35 x 35 ( Millimeters ) |
50 ( Grams ) |
|
Others
Delivery Lead Time |
Supply Ability |
60 days for OEM, 7 days for ready goods |
100 Unit |
60,000 Set/ Sets per Month |
|
|
|