High Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape BandagePipe repair bandage is an extremely convenient and effective product for the emergency repair of less severe pipe leaks on steel,HDPE, rubber hoses, ventilation ducts, plastic both underground and surface application. Quick and simple to use with no mixing or measuring required. A successful pipe repair can be achieved in only 30 minutes.
High Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape BandageResin MakeupWater-activated Polyurethane
Heat Resistance150°C (300°F)
Pressure ResistanceInternal Pressure up to 15Mpa (5075psi)
Bonds to Most Pipes
- Steel
- Polypipe
- PVC
- Fibreglass
- Copper
Set Time20 – 30 minutes, sets under water
Chemical, Fuel and Oil Resistant
- Acid lines
- Oils
- Gas
- Sea water
- MDISC
High Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape Bandage
High Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape BandageFor Pipe Repair Bandage,normal size as below: ( The length can be produced as your need)
High Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape BandageNameModelSizePacking
Pipe Repair BandageUT00250mm x 3.6m (2" x 12´)10rolls x 10rolls/ctn
UT00375mm x 3.6m (3" x 12´)10rolls x 10rolls/ctn
UT004100mm x 3.6m (4" x 12´)10rolls x 10rolls/ctn
UT005125mm x 3.6m (5" x 12´)8rolls x 10rolls/ctn
UT006150mm x 3.6m (6" x 12´)8rolls x 10rolls/ctn
High Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape Bandage* Clean and roughen the damaged area with the metal file or wire brush, which will help resulting a more successful repair.
*Knead Steel Putty and apply firmly into damaged area. Putty has a 2-5 minute work time, and the bandage application must begin during this time.
* Put gloves on,Soak bandage in fresh water for 10 seconds. Squeeze bandage 1-2 times while in water to help activation.
* Squeeze out the access water, apply the bandage spirally around the damaged pipe area. Extending up to 50mm (2″)either side of the leaked area.
* With wet gloves, squeeze the bandage with a rotating motion until resin stops foaming and is set.
Bond in 30 minutes Pipe Repair BandageTips: To achieve the best result,the bandage should be more than 10mm thick (10-15 layers). Allow 30 minutes for bandage to set rock-hard.
High Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape BandageHigh Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape BandageDelivery: 5-7 working days
Pipe Repair Bandage Black Repair Tape made in China Fiberglass BandageHigh Strength Quick Bonding Pipe Repair Bandage Oil Water Pipeline Fix Tape BandageHeadquarter:
Address: 21F, Zimao District, Shaanxi Xi'an,China,PRC
Tel. No.: +86-574-85257751
Fax. No.: +86-574-85567233
Mob. No.: +86 13175174867
Less ...